Product Overview
Engineered to strict European and North American performance standards, our High Thermal Insulation Side-Hung Inward Window System integrates a multi-chamber thermal break architecture, high-density polyamide insulation barriers, and high-performance EPDM sealing systems. Designed specifically for low-energy developments, Passive House structures, and high-end residential or commercial architectural projects, this system addresses the strict energy codes, structural integrity requirements, and acoustic isolation needs of demanding global markets.
Tested & Certified Standard Compliance: Engineered and manufactured in strict compliance with EN 12207 / EN 12208 (European air and water tightness standards), NFRC thermal metrics, ASTM E330 / E283 (North American structural and air infiltration standards), and Qualicoat Class 2 finish specifications.
Documentation & Compliance Support: Full performance documentation, factory test reports, and material compliance certificates are available upon request for architectural review and submittal packages.
Commercial & Supply Chain Specifications
|
Parameter |
Commercial Specification |
Notes for Trade Buyers |
|
Minimum Order Quantity (MOQ) |
100 m² (Standard) / Project-Based for Custom Profiles |
Sample kits and corner mock-ups available upon request |
|
Standard Production Lead Time |
25 – 35 Business Days |
EXW, FOB, CIF, or DDP delivery terms available |
|
Warranty & Lifecycle Guarantee |
10-Year Structural & Coating Warranty / 25-Year Service Life |
Covers surface finish, thermal strip integrity, and seals |
|
BIM / CAD Integration Support |
Autodesk Revit (.RVT), AutoCAD (.DWG), IFC formats |
Downloadable technical drawings available for architects |
|
Customization Scope |
Custom dimensions, dual-color anodizing/powder coat, acoustic glass |
Tailored to project-specific wind load calculation sheets |
Detailed Technical Specifications
|
Parameter / Feature |
Technical Specification |
Verification & Standard Compliance |
|
Profile Structure |
High-precision 6063-T5 / 6063-T6 extruded aluminum alloy |
EN 755 / ASTM B221 structural standards |
|
Overall Thermal Performance (Uw) |
≤ 1.2 W/(m²·K) (Standard Double Glazing) ≤ 0.8 W/(m²·K) (Passive House Triple Low-E) |
Calculated per EN ISO 10077-1 / Compliant with NFRC metrics |
|
Acoustic Isolation Index |
38 dB – 45 dB sound reduction capability |
Tested according to EN ISO 140-3 / ASTM E90 |
|
Air Infiltration Resistance |
Class 4 (Infiltration rates < 0.1 m³/h·m²) |
EN 12207 / ASTM E283 |
|
Water Tightness Performance |
Class E1050 (1050 Pa static water pressure threshold) |
EN 12208 / ASTM E331 |
|
Wind Load Resistance |
Class C5 (2500 Pa service load design pressure) |
EN 12210 / ASTM E330 |
|
Thermal Barrier Strip |
24 mm – 34 mm multi-chamber PA66 GF25 Polyamide |
ISO 14001 certified / Thermal conductivity ≤ 0.3 W/(m·K) |
|
Sealing Architecture |
Continuous triple-layer EPDM gasket system |
ISO 3939 / ASTM C864 weather durability rating |
|
Hardware & Lock Mechanism |
European standard groove multi-point perimeter locking |
EN 13126 tested for 25,000+ continuous operation cycles |
|
Surface Finish Coating |
Qualicoat Class 2 Powder Coating / PVDF Fluorocarbon |
AAMA 2604 / AAMA 2605 (Salt spray resistance > 2000 hours) |
Engineering Features & Structural Logic
1. Advanced Multi-Chamber Thermal Break Technology
Structural Advantage: Combines extruded structural aluminum profiles with 24 mm to 34 mm high-density PA66 GF25 (25% glass-fiber reinforced polyamide) insulation strips.
Why It Works (Engineering Logic): Aluminum is naturally conductive (approx. 200 W/(m·K)). By physically separating the interior and exterior aluminum extrusions with polyamide materials that have a thermal conductivity of less than 0.3 W/(m·K), the thermal bridge is broken. The multi-chamber internal voids isolate dead air, which dramatically minimizes convective heat transfer across the frame profile.
Buyer Impact & Credibility: Directly ensures compliance with European Energy Performance of Buildings Directives (EPBD) and North American ASHRAE 90.1 energy codes, drastically lowering long-term HVAC operational costs for building owners.
2. Ergonomic Side-Hung Inward Opening Functionality
Structural Advantage: Sashes swing inward into the interior room space at a 90° to 180° angle, supported by heavy-duty concealable hinges and friction stays.
Why It Works (Engineering Logic): In mid-rise and high-rise developments, outward-opening windows create severe fall hazards during maintenance and face extreme wind suction forces that can tear open untethered sashes. Inward opening directs positive wind load forces safely against the internal structural stops of the aluminum frame.
Buyer Impact & Credibility: Simplifies exterior glass cleaning completely from inside the building, eliminating expensive external scaffolding or cradle cleaning costs while fulfilling stringent municipal high-rise safety regulations.
3. Triple-Barrier EPDM Weather Sealing Architecture
Structural Advantage: Features three continuous rubber sealing loops: an outer weather seal, a central pressure equalization seal, and an inner acoustic gasket.
Why It Works (Engineering Logic): EPDM retains elastic memory and flexible recovery even under persistent thermal stress between -40 °C and +120 °C. The central equalization chamber creates a pressure-balanced cavity between the exterior frame and sash, forcing wind-driven rain to drain outward through concealed weep holes rather than pushing past internal seals.
Buyer Impact & Credibility: Completely eliminates draft-induced energy losses and prevents internal dampness, structural wood rot, or drywall mold, guaranteeing a multi-decade operational lifespan without seal degradation.
Project References & Custom Engineering
Architectural Submittal Packages: Detailed shop drawings (.DWG/.RVT), structural calculation sheets, and wind load analysis reports are provided for project-specific approvals.
Physical Mock-ups & Samples: Corner sample kits and customized profile section cutaways are available upon request for architectural submittal and physical evaluation.
FAQ
Q: What specific thermal performance level (Uw) can this window system achieve?
A: Depending on the selected glass combination, the overall window system achieves a Uw-value between 1.2 W/(m²·K) (standard double Low-E with Argon) and 0.8 W/(m²·K) (triple Low-E with warm-edge spacers). These performance levels fully meet North American ENERGY STAR requirements and European Passive House criteria.
Q: Why is the inward opening design preferred for commercial and high-rise projects?
A: Inward opening windows offer two key functional advantages for high-rise buildings: safety and maintenance ease. Exterior maintenance and glass cleaning can be performed entirely from inside the room without external scaffolding. Structurally, positive wind loads push inward sashes firmly against the frame stops rather than straining external hinges.
Q: What international building standards apply to this window system?
A: Profile materials, thermal break strips, finishes, and performance parameters comply with international architectural standards including EN 12207 / EN 12208 (European air and water tightness standards), NFRC / AAMA (North American structural and thermal testing metrics), and Qualicoat surface treatment specifications.
Q: How does this system perform in coastal or high-corrosion environments?
A: Surface finishes utilize AAMA 2605-compliant PVDF fluorocarbon coatings or Qualicoat Class 2 powder finishes. Combined with high-grade EPDM gaskets and 304/316 stainless steel hardware components, the system withstands over 2,000 hours of continuous salt spray testing without surface pitting or finish degradation.
Hot Tags: high thermal insulation side-hung inward window, China high thermal insulation side-hung inward window factory, commercial inward opening windows, etched glass inward opening windows, inward opening window system solution, modern building inward windows, Soundproof Inward Casement Window, Thermally Broken Inward Opening Window